              Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
              0517-86918678
              Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
              Tel:0517-86918678
              Fax:0517-86918679
              Email:zhongweick@https://www.szokazaki.com
              Post Encoding:211600

              Furnace wall thermocouple

              18鑪(lu)壁熱電(dian)偶(ou).jpg
              • 18鑪壁(bi)熱(re)電(dian)偶.jpg
              WRNK-191M series Furnace wall thermocouple Mainly used for boiler tube wall, the furnace wall and ot…

              Description:

              Productoverview:
              WRNK-191M series Furnace wall thermocouple Mainly used for boiler tube wall, the furnace wall and other cylinder surface temperature measurement. The armoured element 3-6MM, as a measurement probe, with compensation cable (Yan Changxing), the measuring end welded or bolted in stainless steel sheet composed of temperature. Is the use of armoured elements 4, Phi Phi 5 diameter as temperature probe, lead wire made of cable shape, measuring end screws or welding method of fastening on the heat conducting plate (when using thermal resistance, no welding method), a heat conducting plate is provided with a curved surface matched with the furnace wall or pipe, heat conducting plate by welding or hoop (pipe) in the furnace wall, the heat conduction plate, can measure the wall or other cylindrical surface temperature.
              Two, Structure principle:
              WRNK-191M series Furnace wall thermocouple Is the welding of two different material a conductor or semiconductor A and B together to form a closed loop. When two points of attachment conductor A and B 1 and 2 between the temperature difference between the two, will produce electromotive force, thus forming a size of the current in the circuit, this phenomenon is called the thermoelectric effect. The furnace wall thermal resistance is to use this effect to work.
              Three, wide Application:
              WRNK-191M series of professional power plant furnace wall thermocouple design, can meet the 300 thousand and 600 thousand KW generator set and auxiliary measurement needs. Direct measurement of the production process of -200 degrees ~800 degrees within the range of liquid, steam, gas and solid surface temperature. 
              Four, Main features:
              The thermal response time, reduce the dynamic error;
              Flexible installation;
              Large measuring range;
              High mechanical strength, good pressure resistance;
              Five, Structural requirements:
              Two, the composition of thermocouple thermoelectric 1 pole welding must be strong;
              Good insulation should be between 2 and two thermode each other, to prevent short circuits;
              3, and the free end of the thermocouple compensation wire connection is convenient and reliable;
              4, to protect the casing should be able to guarantee the thermode fully isolated from harmful medium.
              Six, Technical parameters:
              1, accuracy: class I and ii;
              2, nominal pressure: pressure;
              3, bending radius: R = 5D.
              Seven, Types and specifications:

              ModelGraduationThe measuring range of CThe measuring end formSpecifications
              LmmL1mm

              WRNK-191M

              WRNK2-191M

              K0 - 800Insulation type

              One thousand

              Two thousand

              Four thousand

              Five thousand

              Eight thousand

              Fifteen thousand

              Twenty-five thousand

              One thousand

              Two thousand

              Four thousand

              Five thousand

              Eight thousand

              Fifteen thousand

              Twenty-five thousand

              WREK-191M

              WREK2-191M

              E0 - 600

              WRNK-192M

              WRNK2-192M

              K0 - 800The shell type

              WREK-192M

              WREK2-192M

              E0 - 600

              Note:
              1, Thermocouple I according to the ordering protocol;
              2, the protective tube is made of 1Cr18Ni9Ti material, the order according to the agreement.
              Eight, Structure and installation:
               Furnace wall thermocouple

               Furnace wall thermocouple
              Installation method: directly welded on the furnace wall, M8 screws.
              Nine, Design selection and ordering information:
              1, model;
              2, division no.;
              3, precision grade;
              4, fixed form;
              5, the length or depth of insertion. 
              Customer service service commitment:
              1, my company sold Zhongwei Thermocouple series The product within twelve months of quality problems, responsible for free maintenance.
              2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
              3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
              4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
              5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.